T201DCH100 is a transducer of direct and alternating current galvanically isolated from the measuring circuit and extremely compact measurements (96.5 x 68 x 26 mm). The device is in function and in the aspect similar to a standard active CT, but able to measure the continuous and alternating current TRMS component. Thanks to its electrical strength, flexibility of use and limited space, the T201DCH100 is suitable for all measurement applications (accumulators, battery chargers, solar panels, power generation units, DC and AC loads etc.) up to 100 ADC / AAC.
DESCRIPTION:
Transformer of direct or alternating current (± 100 A) with Hall effect TRMS with output 0.10 V
POWER SUPPLY: 12.28 Vdc
PRECISION CLASS: 0.5
INPUT: Continuous Current / Alternate -100. + 100 A
TYPE OF MEASUREMENT: TRMS
OUTPUT: 0..10 V
CONFIGURATION: Via DIP switch
DIMENSIONS: 68 x 95 x 25 mm
SPECIFICATIONS
ENTRANCE
Limit values 0 - 100A / TRMS or -100 - + 100A / Bipolar for DCH100 -
0 - 300A / TRMS or -300 - + 300A / Bipolar for DCH300 -
Measurement type ac / dc TRMS or dc Bipolar
Flow rate T201DCH100
Flow rate T201DCH300
0 - 50A or 0 - 100A TRMS; -50 - + 50A or -100 - + 100A Bipolar
0 - 300A or 0 - 150A TRMS; -150 - + 150A or -300 - + 300A Bipol.
(selected by dip-switch)
Crest factor 2
2.5kHz bandwidth
Insulation DO NOT USE NUDE CONDUCTORS;
With insulated conductors, double insulation up to 300 V CAT II (with respect to Earth) is assured.
Overload 2000 A impulsive, 300 A continuous
OUTPUT AND POWER SUPPLY
Type 0 - 10 Vdc, minimum load R = 2 k. The output has the negative LOAD Ω in common with the power supply. Vout and GND terminals
Connections Extractable terminal 5 mm pitch for cables up to 2.5 mm²
Hole diameter 20.8 mm
Power supply 11.5 - 28V (between Vcc and GND) -
Protections - Inversion of polarity.
- Overtemperature protection.
Absorption 21 mA (excluding load)
PRECISION
Accuracy class
(above 2% of full scale)
Accuracy Scope ~ Accuracy -
100 A or 300 A 0.5% of f.s. 1% of the f.s.
50 A or 150 A 1% of f.s. 2% of the f.s.
Accuracy class
(under 2% of full scale)
Accuracy Scope ~ Accuracy -
100 A or 300 A 1% of f.s. 2% of the f.s.
50 A or 150 A 2% of f.s. 4% of the f.s.
12 bit resolution (4000 points)
Coeff. temperature